Toyota 4Раннер + 1. Maintenance instruction + 2. Maintenance + 3. Engines - 4. Systems of heating, ventilation 4.1. Specifications 4.2. Antifreeze 4.3. Thermostat 4.4. Krylchatka of the fan and hydrocoupling 4.5. Radiator and tank 4.6. Maslookhladitel + 4.7. Pump 4.8. Sensor of temperature of liquid 4.9. Electric motor and chain of the fan of a heater 4.10. Heater radiator 4.11. Control panel conditioning block + 4.12. Central air 4.13. Compressor + 5. Fuel and exhaust systems + 6. Transmissions + 7. Transmission elements + 8. Brake system + 9. Suspension bracket and steering + 10. Body + 11. Electric equipment + 12. Electroschemes
|
Standard arrangement of cables of management of the conditioning block
1. Cable of a zaslonka of airinflow 2. Cable of a mixing zaslonka
|
3. Cable of management of a ventilation stream |
Removal
PERFORMANCE ORDER |
1. Disconnect the battery from weight. |
2. Remove facing of the central panel (see subsection 10.23). |
|
3. Remove handles. |
4. Unscrew control panel screws. |
5. Submit the panel on itself, turn tags and disconnect cables, disconnect sockets. |
|
Installation
PERFORMANCE ORDER |
1. Assembly is carried out upside-down. |
2. Adjust cables. |
3. Check heater work. |
|
Adjustment
Adjustment of a zaslonka of airinflow
|
1. Clip
2. The situation FRESH it (is completely open)
3. The situation RECIRC it (is completely closed) |
Adjustment of a cable of a mixing zaslonka
|
1. Clip
2. Situation COOL/situation WARM |
Adjustment of a cable of a mode of heating
|
1. Clip
2. The situation FACE (in a face)
3. Situation DEF |
PERFORMANCE ORDER |
1. Transfer management handles to the provisions RECIRC, COOL, DEF. |
2. For adjustment of a cable of a zaslonka of airinflow transfer the lever to the situation FRESH, attach a cable and tighten a clip (see fig. Adjustment of a zaslonka of airinflow). |
3. For adjustment of a cable of management by a mixing zaslonka transfer the lever to the situation COOL, attach a cable and tighten a clip, pressing a cable cover (see fig. Adjustment of a cable of a mixing zaslonka). |
4. For adjustment of a cable of a mode of heating transfer the lever to the situation DEF (defrosting), attach a cable and tighten a clip (see fig. Adjustment of a cable of a mode of heating). |
|
Chain check
Scheme of electric equipment of conditioning of salon
1. Electromagnetic coupling 2. Processor control unit 3. Ignition switch 4. Relay of back lamps 5. Switch of back lamps 6. Fan switch 7. Conditioner switch 8. Rheostat |
9. Heater safety lock 10. Electric motor 11. The electronic module (on cars with and/t) 12. Relay of pressure and thermoswitch 13. Main relay of a heater 14. Pulse block of ignition 15. Amplifier |
Table of check of the switch of a back heater
Position of the switch
|
Checked conclusions
|
Tester indication
|
OFF |
|
Chains are not present
|
LO |
2–3
|
The chain is
|
HI |
1–2–3
|
Chains are not present
|
PERFORMANCE ORDER |
1. Check the conditioner switch according to the scheme. |
|
2. Check the heater switch. If results of tests unsatisfactory, the control panel replace. |
|
|
|