Toyota 4 Runner/Hilux/Surf

1987-1998 of release

Repair and car operation



Toyota 4Раннер
+ 1. Maintenance instruction
+ 2. Maintenance
+ 3. Engines
+ 4. Systems of heating, ventilation
+ 5. Fuel and exhaust systems
+ 6. Transmissions
+ 7. Transmission elements
+ 8. Brake system
+ 9. Suspension bracket and steering
+ 10. Body
- 11. Electric equipment
   11.1. Specifications
   11.2. Battery
   + 11.3. Ignition system
   11.4. Coil (and) ignitions
   11.5. Ignition distributor
   11.6. Check and installation of the moment of ignition
   11.7. Block of electronic ignition
   11.8. Induction sensor
   + 11.9. System of a charge of the battery
   + 11.10. Generator
   11.11. System of start-up of the engine
   + 11.12. Starter electric motor
   11.13. Traction relay
   11.14. Tension check
   11.15. Detection of short circuit
   11.16. Check of reliability of grounding
   11.17. Check of integrity of a chain
   11.18. Finding of not closed chain
   11.19. Search of malfunctions
   11.20. Safety locks
   11.21. Fusible crossing points
   11.22. Breakers
   11.23. Relay
   11.24. Breaker of indexes of turn / alarm system
   11.25. Switch of indexes of turn
   11.26. Lock of ignition and lock drum
   11.27. Switch of external lighting
   11.28. Screen wiper switch
   11.29. Lamps of headlights
   11.30. Adjustment of headlights
   11.31. Headlight case
   11.32. Replacement of lamps
   11.33. Receiver and loudspeakers
   11.34. Aerial
   + 11.35. Screen wiper electric motor
   11.36. Switch of heating of back glass
   11.37. Heater of back glass
   11.38. Guard of devices
   11.39. Sound signal
   11.40. Electric drive of mirrors
   11.41. Cruise control
   + 11.42. Window regulator electric drive
   11.43. Electric drive of door locks
   11.44. Safety cushions
+ 12. Electroschemes




11.37. Heater of back glass

GENERAL INFORMATION

The heater consists from thin a provolok, baked with a glass surface.

Small destructions can be repaired a provolok independently.

Check

PERFORMANCE ORDER
1. Include ignition and a heater. Between conclusions of a heater connect the voltmeter. If there is no tension, check a safety lock, the switch and wires.
2. Dress on щуп the voltmeter the combined strip of an aluminum foil and press down a finger to a heater thread in the center.
3. If tension is equal 6В, the thread is serviceable, tension is equal 12В, the thread is torn off (break takes place between the center of a thread and weight). If tension 0 In, the thread is torn off between the center and feeding conclusion of a heater.
4. If threads are serviceable, connect (-) - a heater conclusion to weight. If indications of the voltmeter change, connection with weight the unsatisfactory.
5. It is possible to establish a place of break of a thread conducting aluminum contact on щупе the voltmeter on a thread aside from (+) - a conclusion to (-) - to a heater conclusion. The voltmeter thus connect with (-) - a conclusion. The indication of the voltmeter should fall in a break place sharply.

Repair

PERFORMANCE ORDER
1. Срастить the torn-off thread of a heater it is possible by means of carrying-out epoksidny structure of Dupont N 4817 or equivalent.
2. Disconnect a heater.
3. A steel sponge carefully располируйте the damaged site also wipe alcohol.
4. Impose on the damaged site a mask from a sticky tape.
5. Prepare pitch, being guided by the instruction.
6. Put structure on a crack in a mask, smearing approximately on 18 mm in both parties.
7. 24 hours later unmask.